The figures.

Charging the container

Grid input
2× CEE 125 A, 400 V / 50 Hz
Other AC connections
1× CEE 125 A, 1–2× CEE 63 A, 1–2× CEE 32 A
AC charging power
2× 80 kW
DC input
1× CCS2, 340 kW

Charging vehicles

DC charging points
1× 400 kW, 1× 200 kW
Connector
CCS2, liquid-cooled
Voltage range
300–1000 V DC
AC output
CEE 125 A, 400 V, 80 kW

Storage

Capacity
1,254 kWh
Cell chemistry
LFP, 6 clusters of 209 kWh
Nominal voltage
665 V
Cooling
Liquid (pack), air (room)

Enclosure & safety

Dimensions (L × W × H)
2,991 × 2,438 × 2,591 mm
Weight
approx. 13.5 t
Protection class / corrosion
IP54 / C5
Operating temperature
−30 to +50 °C
Fire protection
Aerosol suppression
Recharging

These connections work.

The container charges from whatever connection is available on site. The stronger the connection, the faster it is full again.

ConnectionCharging powerFrom 5 to 95 %*
DC input CCS2 Direct current, straight into the storageup to 340 kWapprox. 3.3 h
2× CEE 125 A 400 V, alternating current160 kWapprox. 7 h
2× CEE 63 A 400 V, alternating currentapprox. 87 kWapprox. 13 h
1× CEE 125 A 400 V, alternating current80 kWapprox. 14 h
2× CEE 32 A 400 V, site power socketsapprox. 44 kWapprox. 25 h
1× CEE 63 A 400 V, alternating currentapprox. 43 kWapprox. 26 h
1× CEE 32 A 400 V, site power socketapprox. 22 kWapprox. 51 h

* Guide values for a charge from 5 to 95 % (approx. 1,130 kWh), excluding charging losses. Partial charges take correspondingly less time.

Compatible with today’s e-trucks

How current models charge at the container.

Both charging points use the CCS2 standard fitted by all major manufacturers. The 400 kW point covers the highest charging power of today’s series-production trucks.

ModelUsable batteryMax. charging power20 to 80 %*Charges per fill**
Mercedes-Benz eActros 600 Tractor unit600 kWh400 kWapprox. 60 min3
MAN eTGX Tractor unit480 kWh375 kWapprox. 50 min3–4
Volvo FH Electric Tractor unit460 kWh350 kWapprox. 65 min4
DAF XF Electric Tractor unit462 kWh325 kWapprox. 55 min4
Designwerk High Cab Swiss manufacturer, battery set 1000864 kWh350 kWapprox. 1.6 h2

* Guide values at the 400 kW charging point based on manufacturer data (battery, CCS charging power, charging time); the actual charging time depends on temperature and charging curve. ** Charges from 20 to 80 % per storage fill (5–95 %, approx. 1,130 kWh). As of October 2026; brand names belong to their respective manufacturers.

Download brochurePDF, 8 pages, 0.6 MB – all technical data, connections and the practical example to pass on.
Design and energy flow

Simplified functional diagram

Simplified illustration.

Contact